
Constant Current Adapter for Ionic Colloidal Silver Generation
MODEL #: CCA
|
DISCONTINUED |
Description
Warranty
Cost
Ordering
Other Products
What's New?
Frequently
Asked Questions (FAQ's) ![]()
Everything
You Need to Know Before You Buy ![]()
The Constant Current Adapter has been designed to convert the Colloidal Silver electrical output of SOTA's Silver Maker and/or Silver Pulser from a constant-voltage to a constant-current.
Constant Current is the preferred method for making the finest quality Ionic/Colloidal Silver.
Making Ionic/Colloidal Silver using The Constant Current Adapter does not require that you boil the water. Using a Constant Current Output, the Ionic/Colloidal Silver process is greatly simplified. The trade-off is it takes about 2 hours to make a 5-8 PPM solution. The good news is you simply leave the Silver Wires in the distilled water, ensure the Orange LED light comes ON, and wait for about 1.5 to 2 hours.
For converting our Silver Maker and/or Silver Pulser, simply plug the Constant Current Adapter into the Colloidal Silver Wire Jack on the Silver Maker and/or Silver Pulser, and then plug the Silver Wire Holder into the Constant Current Adapter. An Orange LED will come on when the current is flowing properly. Simple and easy.
Putting it all together:
![]() |
Our Constant Current Adapter is extremely versatile. Although it was specifically designed to convert our Ionic/Colloidal Silver units to a Constant Current output, this Adapter can operate totally on its own and supply a Constant Current output for use in Ionic/Colloidal Silver production. With appropriate jacks and plugs (from Radio Shack for example) you can make your own Constant Current Ionic/Colloidal Silver generator from virtually any DC power source.
Here's how to do it:
A unique circuit design allows The Constant Current Adapter to operate from a wide range of input voltages.
Our Electrical Circuit Boards use advanced Surface Mount Technology (SMT) for extreme reliability and miniaturization.
1 Year Parts and Labor Warranty on all internally mounted components.
The Unit:
![]() |
The Constant Current Adapter is housed in an attractive over-molded enclosure.
An Orange LED Light illuminates when the circuit through the
Silver Wires is complete and current is flowing correctly.
The Constant Current Adapter is powered by plugging the 2.5mm
plug into either SOTA's Silver Maker or
Silver Pulser. Furthermore, applying
a voltage directly to the 2.5mm plug will also allow the unit to function
correctly as a Constant Current unit on its own.
Electronics:
The Constant Current Adapter is designed to the highest standards. Our electronic design is unique and efficient making the unit very portable and light-weight.
Specifications:
Dimensions:
The Constant Current Adapter is 1.4" wide x 1.1" long x
0.5" thick (30 mm wide x 28 mm long x 13 mm thick). Casing is
high-impact ABS plastic.
Each Constant Current Adapter comes with:
The Constant Current Adapter
|
How to Make Ionic/Colloidal Silver Plug the Constant Current Adapter jack in the Silver Wire Outlet jack on The Silver Pulser or The Silver Maker. Insert the silver wires into the Silver Holder. Plug the cord from the Silver Holder into the Constant Current Adapter. Place the silver wires in 2 cups of room temperature distilled water. About 75% of the wires should be submerged in the water. Ensure the Silver Wires are more than about an inch from the bottom of the glass. Do not let the Silver Wires to touch the bottom of the glass. Turn The Silver Pulser or The Silver Maker unit ON. The Orange LED Light on the Constant Current Adapter will illuminate when the circuit is complete with a proper current flow. The Orange LED Light will gradually get brighter until the current reaches maximum output. It may take up to 15 minutes to reach maximum brightness. To produce 5-8 PPM, let the process run for about 1½ to 2 hours with most distilled waters. After 2 to 3 hours, the PPM will be in the 9-10 PPM range. The PPM does not increase significantly up to 5 hours. (Pale gold with 10.4 PPM) Turn The Silver Pulser or The Silver Maker unit off and clean the Silver Wires well after use. Larger quantities: The time required to make increasing quantities of ionic/colloidal silver is somewhat linear. Using a dissolved solids (PPM) tester from Hanna Instruments, we found after 4 hours, 4 cups of room temperature distilled water measured 7 PPM and 6 cups of room temperature distilled water measured 4-5 PPM. |
|
Here is the actual schematic circuit diagram for our Constant Current Adapter:
|
| The Constant Current Adapter has a full 1 Year Parts and Labor Warranty on all internally mounted components. Silver Wires and Holders can be ordered through us. |
|
DISCONTINUED Please contact us for Shipping Charges, Rates, and Options Please NOTE: Any duties, taxes, import fees and licenses are the responsibility of the receiver. (We Accept: Visa, MasterCard or Money Order) NOTE: If paying by Money Order, and you reside outside of Canada, please ensure you send an INTERNATIONAL MONEY ORDER. Wholesale inquiries welcome. Please call 1.800.224.0242 or 1.250.770.2023 for details. |
|
Our Policy at SOTA: We encourage you to educate yourself before using any of our units. It's easy to make a decision in desperation rather than based on information. We are a company that believes in self-responsibility for ourselves and our customers. RETURN POLICY: 1) If the unit has not been used at all, you can return it for a full refund (less Shipping Charges) within 30 days. 2) If the unit has been used but unit and case are in new condition, you can return within 30 days with a 20% restocking charge (plus Shipping Charges). With the Magnetic Pulser (MPG) and Water Ozonator (WOZ), the restocking charge will be 10% (plus Shipping Charges). 3) Return postage and insurance are your responsibility. NOTE:
All repairs and returns require an
RMA#. For detailed
instructions and an RMA#
on returning for repair or refund, please contact: Thank you for your understanding. |
| Please note: If you are ordering by Fax, E-Mail, or Mailing us a Money Order please remember to include the following important and necessary information so we can process your order without delays (especially International Orders):
|
(Visa, MasterCard, or Money Order)
|
For inquiries and orders write to:
NOTE: This is NOT a secure page. Please DO NOT e-mail your credit card numbers or other sensitive data. Thank-you! |
Please click HERE for
SOTA's current Products...
Please click HERE for our What's New? page...
Please click HERE for our
Frequently Asked Questions (FAQ's)...
Please click
HERE for
information on what you should know before you buy...